F92-0737
Natural to Unregulated L.P. Gas
Conversion Kit
INSTALLATION INSTRUCTIONS
Installer: Save these instructions for future use!
FAILURETO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
APPLICATION
WARNING
!
This regulated Natural Gas to unregulated L.P. Gas conversion
kit allows the 36C, 36E and 36J Series gas valves to be used
on L.P. gas applications, PROVIDED an external regulator is
used and the inlet pressure does not exceed 14”W.C. This
conversion kit is for use on all single stage, fast and slow
open models only.
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructionsandallapplicablecodesandrequirements
of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, ex-
plosion, or production of carbon monoxide may result,
causing property damage, personal injury, or loss of
life.The qualified service agency performing the work
assumes the responsibility for the proper conversion
of this appliance with this kit.
TO CONVERT FROM NATURAL TO L.P. GAS
1. Remove regulator cover screw.
2. Insert the spring (provided in the conversion kit) through the
hole in the center of the plastic regulator adjustment screw.
3. Insert the blocking pin (provided in the conversion kit) down
into the center of the spring.
Regulator
Cover Screw
4. Replace the regulator cover screw.
5. AttachtheWARNINGlabel(providedinthekit)tothegasvalve
where it can be readily seen. Also attach the small round L.P.
label to the top of the regulator cover screw.
Blocking Pin
Spring
Plastic Regulator
Adjustment Screw
6. If present pilot burner is to be used, the pilot orifice must be
replaced.
ConversionbacktoNaturalGasusemaybemadeatalaterdate
by removing the spring and blocking pin (installed in steps 2 and
3, above) and removing the WARNING and L.P. labels.
Figure 1. 36C model
! WARNING
Regulator Cover
Screw
VALVE CONVERTED FOR USE ON L.P.
GAS. REGULATOR BLOCKED OPEN.
EXTERNAL REGULATOR REQUIRED.
IMPROPER OPERATION COULD RESULT
IN DEATH OR SERIOUS INJURY.
Regulator
Cover Screw
Blocking Pin
Spring
!
MISE EN GARDE
SOUPAPE CONVERTIE POUR USAGE
SUR GAZ DE PÉTROLE LIQUÉFIÉ.
RÉGULATEUR BLOQUÉ EN POSITION
OUVERTE. RÉGULATEUR EXTERNE
NÉCESSAIRÉ. UN FONCTIONNEMENT
INAPPROPRIÉ PEUT PROVOQUER LA
MORT OU DES BLESSURES GRAVES.
Blocking Pin
Spring
Plastic Regulator
Adjustment Screw
WARNING Label
Plastic Regulator
Adjustment Screw
Spring
LP
L.P. Label
Blocking
Pin
Figure 4. Contents of kit
Figure 3. 36J model
Figure 2. 36E model
PART NO. 37-5382E
Replaces 37-5382D
0943
White-Rodgers is a division
of Emerson Electric Co.
|